Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 15.384
Filtrar
1.
J Cardiothorac Surg ; 19(1): 211, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38616249

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) has become widely used in recent years, However, there is also an increasing need for removal of TAVR valves due to prosthetic valve dysfunction (PVD) and the development of infective endocarditis. Surgical aortic valve replacement (AVR) for these patients is risky due to the original patient background and anatomic conditions. Intuity rapid deployment aortic valve (Edwards Lifesciences, Irvine, CA) replacement would be useful for such high risk patients to prevent longer cardiac arrest time and obtain good hemodynamic results. However, there are few reports which present Intuity valve replacement after TAVR explantation. Herein, We report two cases in which we have achieved good hemodynamics with shorter cardiac arrest times by using a rapid deployment valve after TAVR explantation. CASE PRESENTATION: We present 2 cases of successful implantation of the Intuity rapid deployment valve after TAVR explantation. The 84- and 88-year-old female patients had previously received TAVR for severe aortic stenosis with SAPIEN XT (Edwards Lifesciences, Irvine, CA) and developed PVD during follow-up. The TAVR valve was removed carefully, then an Intuity valve was implanted with cardiac arrest times of 69 and 41 min. Both patients had good echocardiographic results with effective orifice area of 2.0 cm2 and 1.2 cm2 and mean trans-aortic plessure gradient of 9 mmHg and 15 mmHg respectively without aortic regurgitation. They were discharged without major complications. CONCLUSIONS: Surgical AVR using a rapid deployment valve is a useful alternative to sutured AVR after TAVR valve explantation. It allows for shorter cardiac arrest times and better postoperative hemodynamics without major complication.


Assuntos
Insuficiência da Valva Aórtica , Parada Cardíaca , Substituição da Valva Aórtica Transcateter , Feminino , Humanos , Idoso de 80 Anos ou mais , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/cirurgia , Remoção de Dispositivo
3.
Urologiia ; (1): 35-40, 2024 Mar.
Artigo em Russo | MEDLINE | ID: mdl-38650404

RESUMO

AIM: To evaluate the effect of antibacterial prophylaxis using oral fosfomycin during the removal of a urethral catheter after radical prostatectomy on the development of urinary tract infection, severity of leukocyturia and bacteriuria, as well as the severity of lower urinary tract symptoms. MATERIALS AND METHODS: A single-center, non-blind, prospective, randomized controlled trial was carried out. The main group included 40 patients, and the control group included 37 patients. In the group 1, patients received two doses of oral fosfomycin, 3 g, namely in the evening on the day of catheter removal (the first dose) and 48 hours after catheter removal (the second dose). In the group 2, patients did not receive any antibacterial prophylaxis after urethral catheter removal. The endpoints of the study were confirmed episodes of urinary tract infection within 1 month after removal of the urethral catheter, leukocyturia and bacteriuria in urinalysis/urine culture) and severity of the lower urinary tract symptoms assessed by IPSS questionnaire. RESULTS: In the group 2, urinary tract infection was noted in 17.1%, while in the group 2 only in 2.6% of patients (p=0.032). Leukocyturia and bacteriuria were significantly less common in the group receiving antibacterial prophylaxis with fosfomycin (18.4% vs. 48.6%, respectively; p=0.006). Positive urine culture was observed in 7.9% vs. 25.7%, respectively (p=0.035). Four weeks after removal of the urethral catheter, the average IPSS score was significantly higher in the group 2 (13.2 vs. 9.5 points; p=0.002). There were no cases of allergic reaction and pseudomembranous colitis associated with C. difficile in both groups. Diarrhea cured with sorbents was noted in 2 patients (5.2%) in fosfomycin group. CONCLUSION: Antibacterial prophylaxis using two oral doses of fosfomycin 3 g on the day of urethral catheter removal and 48 hours after catheter removal after radical prostatectomy appears to be an effective scheme that reduces the incidence of urinary tract infection and the severity of lower urinary tract symptoms, and is characterized by a minimal risk of adverse events. It is necessary to carried out further research and develop clear recommendations for antibacterial prevention in urological interventions requiring prolonged urethral catheterization.


Assuntos
Antibacterianos , Antibioticoprofilaxia , Fosfomicina , Prostatectomia , Cateteres Urinários , Infecções Urinárias , Humanos , Fosfomicina/administração & dosagem , Fosfomicina/uso terapêutico , Masculino , Prostatectomia/efeitos adversos , Prostatectomia/métodos , Pessoa de Meia-Idade , Infecções Urinárias/prevenção & controle , Idoso , Estudos Prospectivos , Antibacterianos/administração & dosagem , Antibacterianos/uso terapêutico , Cateteres Urinários/efeitos adversos , Antibioticoprofilaxia/métodos , Cateterismo Urinário/efeitos adversos , Remoção de Dispositivo
4.
Medicine (Baltimore) ; 103(12): e37457, 2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38518004

RESUMO

PURPOSE: Cosmetic iris implants have a record of high ocular complications and are no longer in use. These complications include glaucoma, corneal decompensation, iris atrophy, uveitis, cataract and retinal detachment. CASE PRESENTATION: We report a case of a 44-year-old lady presented with bilateral total iris atrophy, glaucoma and corneal decompensation after cosmetic artificial iris implantation. The patient underwent bilateral artificial iris removal, glaucoma drainage device for the right eye, and micropulse laser for the left eye. In addition, she underwent phacoemulsification with iris-diaphragm intraocular lens implant for the right. The cornea of the right eye ended up with successful Boston keratoprosthesis after rejection of previous 2 grafts. CONCLUSIONS: To the best of our knowledge, we describe the first report of bilateral total iris atrophy following a cosmetic iris implant accompanied by bilateral glaucoma and corneal decompensation.


Assuntos
Doenças da Córnea , Implantes para Drenagem de Glaucoma , Glaucoma , Doenças da Íris , Feminino , Humanos , Adulto , Doenças da Córnea/complicações , Córnea , Remoção de Dispositivo/efeitos adversos , Pressão Intraocular , Glaucoma/etiologia , Glaucoma/cirurgia , Iris/cirurgia , Implantes para Drenagem de Glaucoma/efeitos adversos
5.
Med J Malaysia ; 79(2): 119-123, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38553913

RESUMO

INTRODUCTION: Tracheostomy is a procedure commonly performed in neurocritical and mechanically ventilated patients in the intensive care unit. Dysphagia and impaired airway protection are the main causes for a delay in tracheostomy decannulation in patients with neurological disorders. Endoscopic evaluation is an objective examination of readiness for tracheostomy decannulation with flexible endoscopic evaluation of swallowing (FEES) as the most commonly used method, yet it requires special expertise and is heavily dependent on its operator in assessing the parameters. A relatively new method for assessing decannulation readiness in neurologic disorder, the Standardized Endoscopic Swallowing Evaluation for Tracheostomy Decannulation (SESETD) was introduced in 2013 by Warnecke, et al. This method includes stepwise evaluation of secretion management, spontaneous swallowing and laryngeal sensitivity. This study aims to find conformity between the SESETD and FEES in assessing readiness for tracheostomy decannulation in patients with neurologic disorders. MATERIALS AND METHODS: This study is a cross-sectional study conducted on 36 neurologic patients at Cipto Mangunkusumo General Hospital which was aimed to find the agreement between two modalities for tracheostomy decannulation readiness, FEES and SESETD based on parameters, standing secretion, spontaneous swallowing and laryngeal sensitivity. RESULT: A total of 36 subjects were examined and 22 of them underwent successful tracheostomy decannulation. The agreement between FEES and SESETD showed significant results with p-value <0.0001 and Kappa value = 0.47. CONCLUSION: There was conformity between FEES and SESETD in evaluating tracheostomy decannulation readiness based on three parameters: standing secretion, spontaneous swallowing and laryngeal sensitivity.


Assuntos
Deglutição , Traqueostomia , Humanos , Estudos Transversais , Traqueostomia/métodos , Remoção de Dispositivo/métodos , Endoscopia , Estudos Retrospectivos
6.
Eur J Cardiothorac Surg ; 65(3)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38479816

RESUMO

OBJECTIVES: To evaluate the safety and feasibility of removing drainage tubes at larger size of air leak in patients with prolonged air leak after pulmonary surgery. METHODS: Ninety-five patients who underwent pulmonary surgery with prolonged air leak in our centre were enrolled in this randomized controlled, single-centre, non-inferiority study. The drainage tube was clamped with a stable size of air leak observed over the last 6 h, which was quantified by gas flow rate using the digital drainage system. The control group (n = 48) and the study group (n = 46) had their drainage tube clamped at 0-20 ml/min and 60-80 ml/min, respectively. We continuously monitored clinical symptoms, conducted imaging and laboratory examinations, and decided whether to reopen the drainage tube. RESULTS: The reopening rate in the study group was not lower than that in the control group (2.08% vs 6.52%, P > 0.05). The absolute difference in reopening rate was 4.44% (95% confidence interval -0.038 to 0.126), with an upper limit of 12.6% below the non-inferiority margin (15%). There were significant differences in the length of stay [16.5 (13-24.75) vs 13.5 (12-19.25), P = 0.017] and the duration of drainage [12 (9.25-18.50) vs 10 (8-12.25), P = 0.007] between the control and study groups. No notable differences were observed in chest X-ray results 14 days after discharge or in the readmission rate. CONCLUSIONS: For patients with prolonged air leak, removing drainage tubes at larger size of air leak demonstrated similar safety compared to smaller size of air leak, and can shorten both length of stay and drainage duration. CLINICAL TRIAL REGISTRATION NUMBER: Name of registry: Gas flow threshold for safe removal of chest drainage in patients with alveolar-pleural fistula prolonged air leak after pulmonary surgery. Registration number: ChiCTR2200067120. URL: https://www.chictr.org.cn/.


Assuntos
Tubos Torácicos , Remoção de Dispositivo , Humanos , Drenagem/métodos , Tempo de Internação , Doenças Pleurais , Pneumonectomia/métodos , Pneumotórax/etiologia , Pneumotórax/diagnóstico , Remoção de Dispositivo/efeitos adversos
7.
Int J Pediatr Otorhinolaryngol ; 179: 111934, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38537449

RESUMO

OBJECTIVE: The study objective is to identify factors that impact the time to decannulation in pediatric patients ages 0 through 18 years who are tracheostomy-dependent. METHODS: This retrospective chart review from January 1, 2005 through December 31, 2020 identified pediatric tracheostomy patients at a single pediatric institution. Data extracted included demographic, socioeconomic factors, and clinical characteristics. Multivariate regression and survival analysis were used to identify factors associated with successful decannulation and decreased time with tracheostomy. RESULTS: Of the 479 tracheostomy-dependent patients identified, 162 (33.8%) were decannulated. Time to decannulation ranged from 0.5 months to 189.2 months with median of 24 months (IQR 12.91-45.71). In the multivariate analysis, patients with bronchopulmonary dysplasia (p = 0.021) and those with Passy-Muir® Valve at discharge (p = 0.015) were significantly associated with decannulation. In contrast, neurologic comorbidities (p = 0.06), presence of gastrostomy tube (p < 0.001), or discharged on a home ventilator (p < 0.001) were associated with indefinite tracheostomy. When adjusting for age, sex, race, ethnicity, and insurance status, for every one month delay in establishment of outpatient otolaryngology care, time to decannulation was delayed by 0.5 months (p = 0.010). For each additional outpatient otolaryngology follow-up visit, time to decannulation increased by 3.36 months (p < 0.001). CONCLUSIONS: Decannulation in pediatric tracheostomy patients is multifactorial. While timely establishment of outpatient care did correlate with quicker decannulation, factors related to medical complexity may have a greater impact on time to decannulation. Our results can help guide institutional decannulation protocols, as well as provide guidance when counseling families regarding tracheostomy expectations.


Assuntos
Remoção de Dispositivo , Traqueostomia , Recém-Nascido , Criança , Humanos , Lactente , Traqueostomia/efeitos adversos , Traqueostomia/métodos , Estudos Retrospectivos , Alta do Paciente
8.
Thromb Res ; 236: 136-143, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38447420

RESUMO

BACKGROUND: While accepted indications for the use of inferior vena cava filter (IVCF) in patients with a venous thromboembolism (VTE) have remained stable, their use continues to be frequent. Retrieval rates are still low, being particularly notable in the population with cancer. This study aims to review the rate of adherence to guidelines recommendation and to compare retrieval rates and complications in both cancer and non-cancer patients. METHODS: A retrospective study was performed including 185 patients in whom an IVCF was placed in Hospital Clinic of Barcelona. Baseline characteristics, clinical outcomes, and IVCF-related outcomes were analyzed. A strongly recommended indication (SRI) was considered if it was included in all the revised clinical guidelines and non-strongly if it was included in only some. RESULTS: Overall, 47 % of the patients had a SRI, without differences between groups. IVCF placement after 29 days from the VTE event was more frequent in the cancer group (46.1 vs. 17.7 %). Patients with cancer (48.1 % of the cohort) were older, with higher co-morbidity and bleeding risk. Anticoagulation resumption (75.3 % vs. 92.7 %) and IVCF retrieval (50.6 % vs. 66.7 %) were significantly less frequent in cancer patients. No significant differences were found regarding IVCF-related complications, hemorrhagic events and VTE recurrence. CONCLUSIONS: SRI of IVCF placement was found in less than half of the patients. Cancer patients had higher rates of IVCF placement without indication and lower anticoagulation resumption and IVCF retrieval ratios, despite complications were similar in both groups.


Assuntos
Neoplasias , Embolia Pulmonar , Filtros de Veia Cava , Tromboembolia Venosa , Humanos , Tromboembolia Venosa/epidemiologia , Filtros de Veia Cava/efeitos adversos , Estudos Retrospectivos , Centros de Atenção Terciária , Resultado do Tratamento , Neoplasias/complicações , Anticoagulantes/uso terapêutico , Embolia Pulmonar/etiologia , Veia Cava Inferior , Remoção de Dispositivo/efeitos adversos
9.
Medicine (Baltimore) ; 103(11): e37525, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38489740

RESUMO

To evaluate the technical feasibility of the alternative snare technique using a 0.018-inch guide wire and 5-French (Fr) catheter for double-J ureteral stent (DJUS) removal. In this retrospective study, 11 DJUS were removed in 9 consecutive patients between July 2023 and October 2023. We evaluated patient characteristics, DJUS characteristics, and procedure characteristics. Out of 11 cases, 8 (72.7%) were successful in removing the DJUS using the alternative snare technique without major complications. The average time between DJUS insertion and removal was 47.4 ±â€…50.0 days. The most common DJUS size was an 8-Fr, with proximal tips predominantly in the proximal ureter and renal pelvis. The mean procedure time for successful cases was 15.2 ±â€…16.8 minutes. Three failed cases, attributed to obstructions like debris, were later successfully addressed using the ALN inferior vena cava filter removal kit, forceps, and modified snare technique. The alternative snare technique using a 0.018-inch guidewire and Fr catheter is safe and effective in cases of DJUS removal.


Assuntos
Ureter , Humanos , Ureter/cirurgia , Estudos Retrospectivos , Estudos de Viabilidade , Remoção de Dispositivo/métodos , Cateteres , Stents
10.
Langenbecks Arch Surg ; 409(1): 98, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38499684

RESUMO

PURPOSE: Magnetic anal sphincter (MAS) augmentation is a novel surgical option for the treatment of fecal incontinence. Current clinical evidence is conflicting. The purpose of this meta-analysis was to report the safety profile, potential benefits, and the functional efficacy of this device. METHODS: The study followed the PRISMA guidelines. Literature databases (Medline, Scopus, Web of Science, CENTRAL) were screened for eligible articles. The primary endpoint was the pooled effect of MAS in the Cleveland Clinic Incontinence Score (CCIS) score. Quality evaluation was based on the ROBINS-I and Risk of Bias 2 tool. RESULTS: Overall, 8 studies with 205 patients were included. MAS resulted in a significant reduction of CCIS values (p = 0.019), and improvement only in the embarrassment domain of FIQoL scores (p = 0.034). The overall morbidity rate was 61.8%. Postoperative adverse events included MAS explantation in 12%, infection in 5.1%, pain in 10% and obstructed defecation in 5.8% of patients. CONCLUSION: The application of MAS in patients with fecal incontinence results in the improvement of some clinical parameters with a notable morbidity rate. Due to several study limitations, further, high-quality RCTs are required to delineate the efficacy and safety of MAS.


Assuntos
Incontinência Fecal , Humanos , Canal Anal/cirurgia , Remoção de Dispositivo , Incontinência Fecal/cirurgia , Fenômenos Magnéticos , Qualidade de Vida , Resultado do Tratamento
11.
BMJ Case Rep ; 17(3)2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38514161

RESUMO

Inferior vena cava (IVC) filters are engineered medical devices deployed in the IVC primarily to prevent a pulmonary embolism from occurring. In this article, we present a case of an IVC filter that was successfully retrieved from a patient after being in place for 34 years. The patient presented to hospital for trauma in which subsequent imaging showed tines of an IVC filter protruding outside of the vessel with one of the tines penetrating the duodenal wall. The filter was successfully removed with no complications. This report adds to the existing literature by yielding an example of an adverse risk that can be associated with the placement of IVC filters. In addition, to the authors' best knowledge, this is the longest reported length of time that an IVC filter has stayed in a patient before being removed, thus adding another intriguing detail to the case.


Assuntos
Embolia Pulmonar , Filtros de Veia Cava , Humanos , Veia Cava Inferior/diagnóstico por imagem , Veia Cava Inferior/cirurgia , Embolia Pulmonar/diagnóstico por imagem , Embolia Pulmonar/etiologia , Embolia Pulmonar/prevenção & controle , Remoção de Dispositivo , Filtros de Veia Cava/efeitos adversos , Fatores de Tempo , Estudos Retrospectivos
12.
J Med Case Rep ; 18(1): 103, 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38475904

RESUMO

BACKGROUND: Use of ureteral stents has become an integral part of urological practice. However, it also brought with it many complications. Double J (DJ) stent knotting is a rare stent complication, and only a few cases have been reported in the literature. Although the exact cause is unknown and, in the literature, it is generally thought that knots occur due to traction. In this case report we present for the first time that spontaneous knots can occur due to ureteral peristalsis or ureteral anomalies. CASE PRESENTATION: Two patients (67 and 35 aged-Caucasian person) with ureteral stones who presented to the emergency department with colicky pain and had no previous history of urological surgery. We observed knot formation in the routine urinary system radiographs taken before stent removal in two patients whose ureters were observed to be narrow during endoscopic ureteral stone treatment. The stents were successfully removed using gentle traction under general anesthesia. CONCLUSIONS: We discussed the cause and solution of spontaneous knot formation. We emphasized the importance of the direct urinary system radiograph taken before DJ stent removal.


Assuntos
Ureter , Idoso , Humanos , Remoção de Dispositivo , Stents , Adulto
13.
J Cardiovasc Electrophysiol ; 35(5): 1050-1054, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38501328

RESUMO

INTRODUCTION: Tricuspid regurgitation is associated with significant morbidity and mortality, and occurs at a higher rate in patients with cardiovascular implantable electronic devices. Percutaneous strategies for managing tricuspid regurgitation are evolving, including the development of bicaval valve implantation which has been successfully used in patients with pacing leads. METHODS AND RESULTS: We present the first documented case of lead failure following TricValve® implantation, a dedicated self-expanding system for bicaval valve implantation, and the first successful lead revision procedure in this setting. CONCLUSION: The case illustrates important considerations in undertaking percutaneous intervention in patients with cardiovascular implantable electronic devices, and their ongoing management.


Assuntos
Desfibriladores Implantáveis , Falha de Equipamento , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Masculino , Idoso , Resultado do Tratamento , Reoperação , Desenho de Prótese , Remoção de Dispositivo , Feminino , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/efeitos adversos
15.
Semin Dial ; 37(3): 273-276, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38432229

RESUMO

Mechanical problems like break or crack in Luer connectors or hubs, clamps, and tubings are common non-infectious complications of tunneled dialysis catheters (TDC), which may lead to other TDC complications and the need to insert a new catheter. These can be tackled using TDC repair kits or spare parts, which are often not available, resulting in the insertion of a new TDC that increases morbidity, TDC-related procedures, and healthcare costs. We discuss two cases of broken Luer connections of TDC, which were managed by exchanging the broken Luer connector of TDC with the similar Luer connector of a temporary dialysis catheter. Both the repaired TDCs are thereafter functioning well. This improvised technique provides an easy, effective, long-lasting option that salvages the existing TDC and reduces the cost factor.


Assuntos
Cateteres de Demora , Falha de Equipamento , Diálise Renal , Humanos , Diálise Renal/economia , Diálise Renal/instrumentação , Cateteres de Demora/efeitos adversos , Cateteres de Demora/economia , Masculino , Falência Renal Crônica/terapia , Pessoa de Meia-Idade , Cateterismo Venoso Central/efeitos adversos , Cateterismo Venoso Central/economia , Cateterismo Venoso Central/instrumentação , Análise Custo-Benefício , Feminino , Remoção de Dispositivo/métodos , Remoção de Dispositivo/economia , Desenho de Equipamento
16.
J Cardiovasc Electrophysiol ; 35(5): 929-938, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38450808

RESUMO

INTRODUCTION: Transvenous leads have been implicated in tricuspid valve (TV) dysfunction, but limited data are available regarding the effect of extracting leads across the TV on valve regurgitation. The aim of this study is to quantify tricuspid regurgitation (TR) before and after lead extraction and identify predictors of worsening TR. METHODS: We studied 321 patients who had echocardiographic data before and after lead extraction. TR was graded on a scale (0 = none/trivial, 1 = mild, 2 = moderate, 3 = severe). A change of >1 grade following extraction was considered significant. RESULTS: A total of 321 patients underwent extraction of a total of 338 leads across the TV (1.05 ± 0.31 leads across the TV per patient). There was no significant difference on average TR grade pre- and postextraction (1.18 ± 0.91 vs. 1.15 ± 0.87; p = 0.79). TR severity increased after extraction in 84 patients, but was classified as significantly worse (i.e., >1 grade change in severity) in only 8 patients (2.5%). Use of laser lead extraction was associated with a higher rate of worsening TR postextraction (44.0% vs. 31.6%, p = 0.04). CONCLUSION: In our single-center analysis, extraction of leads across the TV did not significantly affect the extent of TR in most patients. Laser lead extraction was associated with a higher rate of worsening TR after extraction.


Assuntos
Remoção de Dispositivo , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/etiologia , Insuficiência da Valva Tricúspide/diagnóstico , Masculino , Feminino , Remoção de Dispositivo/efeitos adversos , Idoso , Resultado do Tratamento , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Valva Tricúspide/fisiopatologia , Valva Tricúspide/cirurgia , Valva Tricúspide/diagnóstico por imagem , Desfibriladores Implantáveis , Fatores de Tempo , Marca-Passo Artificial , Idoso de 80 Anos ou mais , Dispositivos de Terapia de Ressincronização Cardíaca
17.
Int J Rehabil Res ; 47(2): 97-102, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38451479

RESUMO

After severe brain injuries, a tracheostomy tube is usually inserted for respiratory support. This study aimed to clarify the prognostic factors for tracheostomy early decannulation in patients with acquired brain injuries. We retrospectively reviewed the medical records of inpatients with acquired brain injuries who underwent successful tracheostomy decannulation between March 2021 and June 2022. Fifty-six patients were included; median age was 68 (59-72) years; 28 (50%) were men; 28 (50%) underwent tracheostomy due to stroke. The median time to decannulation was 47 days. The patients were divided into the early and the late decannulation groups based on the median time, and compared. In univariate analysis, the early decannulation group had a higher BMI, peak cough flow, and acquired brain injuries due to trauma, and a lower penetration-aspiration scale score, duration of antibiotic use, and duration of oxygen use. Multivariate Cox regression analysis revealed that a higher initial peak cough flow [hazard ratio (HR) 1.142; 95% confidence interval (CI) 0.912-0.954; P  < 0.001] and lower duration of oxygen use (HR 0.930; 95% CI 0.502-0.864; P  = 0.016) were independent factors for early tracheostomy decannulation, with each unit increase in peak cough flow corresponding to a 14.2% increase and each additional day of duration of oxygen use corresponding to a 7.0% decrease in the likelihood of early decannulation. In conclusion, key prognostic factors for early tracheostomy decannulation were identified as the initial cough strength and duration of oxygen use. These results could play important role in decannulation plans for patients with tracheostomy tube.


Assuntos
Lesões Encefálicas , Traqueostomia , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Prognóstico , Lesões Encefálicas/reabilitação , Remoção de Dispositivo , Fatores de Tempo
18.
Pacing Clin Electrophysiol ; 47(5): 626-634, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38488756

RESUMO

BACKGROUND: Long-term outcomes of sterile lead management strategies of lead abandonment (LA) or transvenous lead extraction (TLE) remain unclear. METHODS: We performed a retrospective study of a population residing in southeastern Minnesota with follow-up at the Mayo Clinic and its health systems. Patients who underwent LA or TLE of sterile leads from January 1, 2000, to January 1, 2011, and had follow-up for at least 10 years or until their death were included. RESULTS: A total of 172 patients were included in the study with 153 patients who underwent LA and 19 who underwent TLE for sterile leads. Indications for subsequent lead extraction arose in 9.1% (n = 14) of patients with initial LA and 5.3% (n = 1) in patients with initial TLE, after an average of 7 years. Moreover, 28.6% of patients in the LA cohort who required subsequent extraction did not proceed with the extraction, and among those who proceeded, 60% had clinical success and 40% had a clinical failure. Subsequent device upgrades or revisions were performed in 18.3% of patients in the LA group and 31.6% in the TLE group, with no significant differences in procedural challenges (5.2% vs. 5.3%). There was no difference in 10-year survival probability among the LA group and the TLE group (p = .64). CONCLUSION: An initial lead abandonment strategy was associated with more complicated subsequent extraction procedures compared to patients with an initial transvenous lead extraction strategy. However, there was no difference in 10-year survival probability between both lead management approaches.


Assuntos
Remoção de Dispositivo , Humanos , Masculino , Feminino , Estudos Retrospectivos , Idoso , Minnesota/epidemiologia , Desfibriladores Implantáveis , Marca-Passo Artificial , Resultado do Tratamento , Pessoa de Meia-Idade , Eletrodos Implantados
19.
BMC Nephrol ; 25(1): 104, 2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38500070

RESUMO

BACKGROUND: Tunnelled cuffed haemodialysis catheters are at increased risk of incarceration or becoming 'stuck' via fibrotic adhesion to the central veins when left in situ for prolonged periods of time. Stuck catheters cannot be removed using standard techniques such as bedside dissection of the cuff. Whilst there are several strategies published for the removal of these incarcerated lines, there is no consensus on the best approach. Here we present a challenging case of a stuck haemodialysis catheter in the acute post transplantation period. CASE PRESENTATION: A 66-year-old female on haemodialysis presented for kidney transplantation with a tunnelled-cuffed haemodialysis catheter in situ for five years. Following transplantation, removal of the line was unsuccessful despite dissection of the cuff, with traction causing a choking sensation with tracheal movement. Eventually, the line was removed without complications utilising sequential balloon dilatation by interventional radiology and the patient was discharged without complications. CONCLUSIONS: This case serves as a timely reminder of the risks of long-term tunnelled haemodialysis catheters and as a caution towards proceeding with kidney transplantation in those with long-term haemodialysis catheters in situ. Greater nephrologist awareness of interventional radiology techniques for this challenging situation will help to avoid more invasive strategies. The risks of a stuck catheter should be included in the discussions about the optimal vascular access and transplantation suitability for a given patient.


Assuntos
Cateterismo Venoso Central , Transplante de Rim , Feminino , Humanos , Idoso , Cateterismo Venoso Central/efeitos adversos , Cateteres de Demora/efeitos adversos , Transplante de Rim/efeitos adversos , Remoção de Dispositivo , Diálise Renal/efeitos adversos
20.
Knee Surg Sports Traumatol Arthrosc ; 32(5): 1096-1104, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38461373

RESUMO

PURPOSE: To investigate the landing strategies used after discontinuing and continuing the use of a functional knee brace (FKB) while performing a drop jump. METHODS: Following published methodology and power analysis, 23 uninjured male athletes, mean age of 19.4 ± 3.0 years, performed seven tests, during three test conditions (nonbraced, braced and removed brace or continued brace use), over 6 days of 12 testing sessions (S) for a total of 38.5 h. Each subject was provided with a custom-fitted FKB. This study focuses on the single leg drop jump kinetics during S12 when subjects were randomly selected to remove the FKB after 17.5 h or continued use of FKB. The time to peak vertical ground reaction forces (PVGRF) and PVGRF were recorded on landing in eight trials. RESULTS: After brace removal, a significantly shorter mean time to PVGRF was recorded (9.4 ± 22.9 msec (3.9%), p = 0.005, 95% confidence interval (95% CI): -168.1, 36.1), while continued brace use required a nonsignificant (n.s.) longer mean duration to achieve PVGRF (19.4 ± 53.6 msec (8.9%), n.s., 95% CI: -49.7, 73.4). No significant mean PVGRF difference was found in brace removal (25.3 ± 65.8 N) and continued brace use (25.1 ± 23.0 N). CONCLUSION: Removal of FKB after 17.5 h of use led to a significantly shorter time to achieve PVGRF, while continued brace use for 21 h required a longer duration to achieve PVGRF, suggesting faster and slower knee joint loading, respectively. Understanding the concerns associated with the use of FKB and the kinetics of the knee joint will assist clinicians in counselling athletes about the risks and benefits of using an FKB. LEVEL OF EVIDENCE: Level II.


Assuntos
Braquetes , Articulação do Joelho , Humanos , Masculino , Articulação do Joelho/fisiologia , Adulto Jovem , Fenômenos Biomecânicos , Fatores de Tempo , Suporte de Carga , Adolescente , Adulto , Remoção de Dispositivo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...